0102030405
China 3 Phase 110VDC 40A Economy Charger - Reliable Power Supply from Trusted Suppliers & Factory
System Performance
110V natural cooling rectifier is the most favorable product with distinctive design. By using radiator instead of fan, it achieves high adaptability on operation conditions and high reliability.
Main Features
Product Parameter
| Technical Specification | |
| Model BZA- | 110D40ZZ-3 |
| AC Input | |
| Input voltage | 380VAC ± 20% |
| Input phase | 3-Phase |
| Power factor | ≥ 93% |
| Input frequency | 45 to 65 Hz |
| DC Output | |
| Output voltage | 95–150 VDC (Nominal 110 VDC) |
| Default output voltage | 117 VDC |
| Rated output current | 40 A |
| Max output power | 6000 W |
| Output current limit | 105% rated output current |
| Efficiency | ≥ 94% |
| Voltage accuracy | ± 0.5% |
| Current accuracy | ± 1% |
| Ripple | ≤ 0.2% |
| Load share imbalance | ≤ ± 3% |
| Features | |
| Communication interface | RS485 |
| Load capability | 100% continuous output current |
| Indicators | LED indicator for AC mains, rectifier failure, over temperature; Digit fault code on LCD display |
| Protection and alarms | Input under/over voltage, output under/over voltage, output current limit, over temperature, short circuit protection, phase loss |
| Insulation | 2.1 kVac input-earth 2.1 kVac input-output 2.1 kVac output-earth |
| Mechanical | |
| Weight | 16 kgs |
| Environmental | |
| Cooling method | Natural cooling |
| Temperature rise | ≤ 30 ℃ |
| Noise | < 50 dB |
| Storage temperature | -40 / +60 ℃ |
| Working temperature | -10 / +40 ℃ |
| Humidity | 95% RH non-condensing |
| Altitude | ≤ 2000 m |
Frequently Asked Questions
Q
What is the cooling method used in the BZA-110D40ZZ-3 rectifier?
The BZA-110D40ZZ-3 uses natural cooling via a radiator instead of a fan. This design eliminates noise from forced air cooling, improves reliability, and makes the unit suitable for a wide range of operating environments without the mechanical wear associated with fan-based systems.
Q
What is the rated output voltage and current of this rectifier module?
The rectifier provides a DC output voltage range of 95–150 VDC (nominal 110 VDC), with a default output voltage of 117 VDC. The rated output current is 40 A, and the maximum output power is 6000 W.
Q
Does the BZA-110D40ZZ-3 support hot-swap replacement?
Yes, the module supports hot-swappable operation, allowing maintenance personnel to replace or install the unit without powering down the entire system. This feature significantly reduces downtime and simplifies maintenance procedures.
Q
What protection functions are built into this rectifier?
The rectifier includes comprehensive protection and alarm functions: input under/over voltage protection, output under/over voltage protection, output current limiting (at 105% rated current), over-temperature protection, short circuit protection, and phase loss protection. LED indicators and LCD fault codes provide real-time status monitoring.
Q
What are the operating and storage temperature ranges for this unit?
The working temperature range is -10 °C to +40 °C, making it suitable for most indoor telecom and industrial environments. The storage temperature range is -40 °C to +60 °C. The unit also supports operation at altitudes up to 2000 m and humidity up to 95% RH (non-condensing).
Q
What communication interface does the rectifier support, and can it be used in a redundant configuration?
The BZA-110D40ZZ-3 is equipped with an RS485 communication interface, enabling remote monitoring and control. It also supports a modular N+1 redundancy design, meaning one or more backup modules can be added to ensure system continuity in the event of a single module failure.